您的当前位置:首页正文

Balluff_Sensor-BES 516-326-s4-c_en

2023-01-05 来源:我们爱旅游
Inductive Sensors

BES 516-326-S 4-C

cyl. M18 Sn = 5 mm DC 3-Wire shielded

Common Data

Mounting shielded

额定工作距离确定工作距离Rated operating distance Sn Assured operating distance Sa mm mm

5,0 0...4.0

Repeatability % <= 5

<= 15

迟滞Hysteresis % Function indication

Ambient temperature range Polution Degree

°C

yes -25...+70 3

IEC-Code I1A18AP2 Time delay before availability

ms

<= 10

Mechanical Data

Housing size

Measurements BxHxT or DxT Housing material Material of sensing face

mm mm

cyl. M18 M18x1 x 83 nickel plated brass PA 12

IP68 acc. BWN Pr 20

Degree of protection

Connection Connector S4

Utilization categories DC 13

Electrical Data

Current type

DC

Wiring 3-Wire

switching function Output signal

Rated operational voltage Rated operational current

V mA V

normally-open PNP 24 DC 200 10...30 DC

Tightening torque: Supply voltage

Ripple % <= 15 Rated supply frequency No-load supply current Off-state current

Hz mA µA V

900

<= 12/<= 4 <= 10 <= 1.5/- yes yes

Torque 1 Nm 35

If only torque1 is indicated, this applies to entire thread

If not differently indicated,

all values by IEC 60947-5-2 (DIN EN60947-5-2) Specifications subject to change

Balluff GmbH Postfach 1160

73761 Neuhausen

Telefon (07158) 173-0 Telefax (07158) 5010

Voltage drop

Short circuit protection

Protected against polarity reversal

25.05.2004 / Online-Information